2PCS ECM Power Relay 39794-SDA-901 Replaces 39794-SDA-902, Compatible with Honda Accord 2003-2022, CR-V 2007-2022, Odyssey 2005-2022, Pilot 2009-2024, 12V 4-Pin Engine Bay Relay

★★★★★ 4.5 137 reviews

US$3.20
Price when purchased online
Free shipping Free 30-day returns

Sold and shipped by museoboladeoro.com
We aim to show you accurate product information. Manufacturers, suppliers and others provide what you see here.
US$3.20
Price when purchased online
Free shipping Free 30-day returns

How do you want your item?
You get 30 days free! Choose a plan at checkout.
Shipping
Arrives Aug 26
Free
Pickup
Check nearby
Delivery
Not available

Sold and shipped by museoboladeoro.com
Free 30-day returns Details

Product details

Management number 237389642 Release Date 2026/07/10 List Price US$3.20 Model Number 237389642
Category

What it is: ECM/PCM power relay (12V, 4-pin) for engine management power feed. Direct reference: 39794-SDA-901; supersession: 39794-SDA-902.Function & symptoms: Supplies switched battery voltage to the engine control module. Failure may cause no-start, intermittent stall, or ECM power faults (e.g., P0685); verify power and grounds during diagnosis.Typical location: Main fuse/relay box in the engine compartment on many applications; some models use an interior (under-dash) fuse/relay box. Always confirm by VIN/owner’s manual.Fitment highlights (North America): Compatible with Honda Accord (2003–2022), CR-V (2007–2022), Odyssey (2005–2022), Pilot (2009–2024); Compatible with Acura RDX (2007–2024), MDX (2014–2024), TL (2004–2014), TSX (2004–2014). For exact trim/engine coverage, match by VIN.Complementary parts: Pair with fuel pump relay OE 39794-SDA-004 when addressing no-start/fuel-delivery issues from the same fuse/relay box.Notes: This listing references OE numbers for identification. Verify slot position and relay footprint before installation.

  • Specs & OE cross-refs — 12V control relay; 4-pin configuration; engine/ECM power function. Cross-reference OE: 39794-SDA-901 (this listing); replaces/superseded by 39794-SDA-902. Typical symptoms of a failing ECM/PCM power relay include no-start, intermittent stall, or ECM power faults (e.g., P0685).
  • Install location & service notes — Typically installed in the main fuse/relay box in the engine compartment; some applications may use an interior (under-dash) fuse/relay box. Verify by VIN/owner’s manual before installation. “Included with main fuse box” is noted on OE catalogs for the superseding part. Basic check: swap-test with like relay, or bench-test coil/contacts before replacement.
  • Compatible with 2003–2022 Honda Accord (Engine Compartment Fuse/Relay Box ECM Power Relay) — years covered for North America: 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018, 2019, 2020, 2021, 2022.
  • Compatible with 2007–2022 Honda CR-V (Engine Compartment Fuse/Relay Box ECM Power Relay) — years: 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018, 2019, 2020, 2021, 2022
  • Compatible with 2005–2022 Honda Odyssey (Engine Compartment Fuse/Relay Box ECM Power Relay) — years: 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018, 2019, 2020, 2021, 2022.
  • Compatible with 2009–2024 Honda Pilot (Engine Compartment Fuse/Relay Box ECM Power Relay) — years: 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018, 2019, 2020, 2021, 2022, 2023, 2024
  • Compatible with Acura (ECM Power Relay, Fuse/Relay Box) — RDX years: 2007–2024 (list: 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018, 2019, 2020, 2021, 2022, 2023, 2024); MDX years: 2014–2024 (2014, 2015, 2016, 2017, 2018, 2019, 2020, 2021, 2022, 2023, 2024)
  • More Acura coverage (ECM Power Relay, Fuse/Relay Box) — TL years: 2004–2014 (2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014); TSX years: 2004–2014 (2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014)
  • Complementary items to capture related traffic — Compatible with OE fuel-pump relay 39794-SDA-004 (often serviced from the same fuse/relay box); pairing this ECM power relay with the fuel-pump relay and appropriate fuses can resolve “crank/no start with fuel cut” complaints. Check fuse box diagrams for exact slots.
ASIN B0FWKMF79V
Brand Name Kwaich
Unit Count 2.0 Count
Part Number 39794-SDA-901-248-2
Coil Voltage 12 Volts (DC)
Contact Type Normally Open
Manufacturer RZ
Mounting Type RM
Connector Type 4-pin
Operation Mode Automatic
Contact Material Silver
Minimum Switching Voltage 12 Volts (DC)

Correction of product information

If you notice any omissions or errors in the product information on this page, please use the correction request form below.

Correction Request Form

Customer ratings & reviews

4.5 out of 5
★★★★★
137 ratings | 56 reviews
How item rating is calculated
View all reviews
5 stars
83% (114)
4 stars
4% (5)
3 stars
2% (3)
2 stars
1% (1)
1 star
10% (14)
Sort by

There are currently no written reviews for this product.